Professional HVAC cleaning

HVAC cleaning — results you can see.

In a contaminated HVAC system, bacteria, dust, mold and pollen accumulate. We remove them — and prove it with a laboratory analysis.

Bacteria
Dust
Mold spores
Pollen
Clean air
Move your mouse — wherever you go, the air is clean

Why clean your HVAC system

Employee health

A clogged HVAC system spreads dust, mold and bacteria. Clean air reduces sickness rates and sick-building syndrome.

Fire safety

Greasy dust settled in the ducts is flammable. Regular cleaning is part of fire prevention for commercial premises.

Lower consumption

Clogged heat exchangers force the system to run at higher output. A clean HVAC system means lower energy bills.

Legislation and hygiene

Premises with mechanical ventilation are required to document cleaning. We issue a report for inspections.

Our services

Complete HVAC cleaning

We specialize exclusively in HVAC systems — from coolers and ductwork to terminal units. Everything with measurements, a report, and photo documentation.

Technician cleaning air ducts with a rotary brush — HVAC cooling plant room
01

Air-duct cleaning

Deep cleaning of air-handling ductwork with rotary brushes and negative pressure. We remove dust, grease, and biological deposits along the entire length of the ducts.

Rotary brushesNegative pressureCamera
02

Fan-coil units

Disassembly, filter replacement, cleaning of the heat exchanger, fan, and condensate tray. Disinfection and reassembly. We restore the unit's original performance and hygiene.

Heat exchangerDisinfection
03

Induction units

Cleaning of induction units including nozzles and finned heat exchangers. Sensitive equipment requires a precise procedure — one we have mastered.

NozzlesFins
04

Diffusers and grilles

Disassembly, washing, and disinfection of the system's terminal elements. Diffusers are the most visible part — and the first thing you notice after cleaning.

DisassemblyDisinfection
05

Dry coolers

Cleaning of the finned blocks of dry coolers and condensers. Clogged fins impair cooling — we restore airflow and efficiency.

Finned blocksPressure
06

Split units and air conditioning

Complete servicing and cleaning of split air conditioners — evaporator, fan, filters. Disinfection against mold and odors for a healthy indoor climate.

EvaporatorFiltersAnti-mold
How we work

From analysis to protocol

The laboratory is an optional add-on service. We take samples and determine whether cleaning is worthwhile. Laboratory analysis must be requested separately — it is not automatically part of the quote.

On request

Sample collection

We take swabs and samples from the ducts for laboratory analysis. This service is not part of the standard offering — to use it, you need to request it in advance.
Laboratory
1
Optional

Camera inspection

We inspect the condition of the ducts and units with a camera and define the scope.
2
Within 3 days

Price quote

An itemised quote with a fixed price and a schedule tailored to your operations.
3
No downtime

Cleaning work

We work outside business hours — evenings, weekends and holidays — so that office staff are not burdened by dust and noise.
4
Documentation

Protocol and photos

A cleaning protocol, before/after photos and a recommended maintenance interval.
Laboratory

First we measure. Then we clean.

Don't want to pay for cleaning blindly? We take samples from your air-handling system and, in a contracted accredited laboratory, determine the actual condition — how much contamination is present and of what kind. Only then do we decide together.

Microbiological analysis
We determine the type and quantity of bacteria, mold, and other microorganisms in the samples.
Documented result
You receive a protocol with measured values — proof of the condition both before and after cleaning.
No unnecessary costs
If the analysis shows that cleaning isn't needed, you save. If it is needed, you know exactly why.
FTIR6components
Amorphous carbon
from the V-belt
43%
Polyester
textile fibers
21%
Silicates
inorganic salts
16%
Cellulose
paper and organics
11%
Polyethylene
synthetic fibers
5%
Wool and amides
clothing textiles
4%
Real-world case

Amorphous carbon made up over 40% of the dust — degraded rubber from the V-belt travelled straight into the offices for several months.

Contract lab · ČSN EN ISO/IEC 17025 · TUL Liberec
Microbiology

Before and after cleaning — in numbers.

We took microbiological swabs at seven locations before and after the HVAC cleaning. The results were analyzed by the Public Health Institute in Hradec Králové (accreditation no. 1388).

36 000
< 5
CFU / swab · one location · one job

Contracted accredited laboratory · ČSN EN ISO/IEC 17025 · microbiological swabs on request

0log↑ · CFU / swab36 000
Vestibule
36 000
HVAC outlet
380
Billiard room
70
Children's room
20
Pool
10
Bedroom A
< 5
Bedroom B
< 5
before cleaning
after cleaning (< 5)
Client data is anonymized
Request a similar protocol
Protocol

Every job ends with a document, not a promise.

After every cleaning we issue a test protocol with the measured values before and after. The document is issued by a contracted accredited laboratory — not by us. That means the result is independent and verifiable during a hygiene inspection or an internal audit.

  • ČIA accreditation No. 1388 · ČSN EN ISO/IEC 17025
  • Values before and after cleaning — in the same document
  • A valid supporting document for hygiene inspections
  • We commission the laboratory; you pay as part of the job
Case study

From odor to diagnosis in 72 hours.

Step 1 · Problem
Irritating air, unknown cause.

Employees complain of pungent air and a persistent odor. The building owner ruled out a gas leak and sewer problems. The ventilation works — but the problem persists.

Step 2 · Analysis
Sampling. FTIR spectroscopy.

We took wipe samples from the ducts and filters. A contracted laboratory performed an FTIR analysis of the dust fraction's composition.

Finding
43 %

amorphous carbon from a degraded V-belt in the HVAC unit — the source was directly above the offices.

Step 3 · Result
Belt replacement. Deep cleaning.

After replacing the belt and cleaning the entire duct run: no complaints, no repeat call-outs. A condition report was handed over to the client.

Laboratory-issued report on the result of the HVAC cleaning
Technology & equipment

Professional equipment, not improvisation

We work with certified equipment for HVAC cleaning. Here's a selection of what we use to achieve a measurable result.

Wöhler SI 400 inspection camera, flexible shaft and rotary brushes ready for use
Vacuum
HEPA M / H
Class M and HDIN EN 60335-2-69Discharge into ducts
Industrial negative-pressure unit

Certified HEPA filtration for health-hazardous dust of classes M and H. It captures dust directly into the filter cartridge — nothing is released back into the air.

Cleaning · Wöhler
Snap&Sweep®
Soft filamentHVAC + heat recoveryØ 80–250 mm
Rotary cleaning system

A rotary head with soft filaments for the mechanical cleaning of air ducts and heat-recovery exchangers. Cleans without damaging the duct surface.

Inspection · Wöhler
SI 400
HD resolutionM5 / M10 reelSD card recording
Smart Inspection Camera

Camera documentation of the duct interior before and after cleaning. We hand the HD video recording to the client as part of the HVAC condition report.

Cleaning · Wöhler
Flexible shaft
5 m setØ 140 mm headReplaceable strips
Flexible shaft + brush set

An electrically driven flexible shaft with a Ø 140 mm brush head. Cleans bent runs and hard-to-reach ducting, and the brush strips can be swapped without tools.

Marimer in numbers

2009
On the market since
3
We cover all of Czechia
100%
Jobs with a protocol
B2B
Specialized in businesses
Standards and assurances

We do it by the book

Cleaning protocol

A record with every job — for the health authority, the fire-safety inspector, and your own documentation.

Liability insurance

We are insured to work on client premises, including sensitive environments.

Work outside operating hours

Night and weekend slots so cleaning never disrupts your operations.

Recommended interval

We propose a regular maintenance schedule based on your type of operation and load.
References

Trusted by businesses and facility managers alike

We work for production halls, office buildings, restaurants, and healthcare facilities. What connects them is the need for demonstrably clean air.

"

The HVAC cleaning across the entire office building was carried out over the weekend, and on Monday operations ran without any restrictions. We filed the report and photos straight into our occupational health and safety documentation.

JK
Jan Konečný
Facility manager, Brno
"

We run a restaurant, and the grease deposits in the air ducts were a hazard. Marimer did precise work — the before-and-after camera footage speaks for itself.

PN
Petra Nováková
Restaurant owner, Prague
"

We had the fan-coil units in our consulting rooms cleaned and disinfected. The before-and-after laboratory analysis was an excellent basis for the hygiene inspection.

MUDr. Martin Šimek
Polyclinic, Hradec Králové
Production hallsOffice buildingsHospitalityHealthcareFacility management
FAQ

The questions we hear most

Standards, intervals, the protocol and how a job runs — clearly in one place.

Which standards do you follow when cleaning HVAC systems?+

For HVAC cleaning we use industrial negative-pressure units with HEPA filtration of dust classes M and H per DIN EN 60335-2-69, capturing hazardous dust directly into the filter cartridge. Microbiological analyses (swabs) are carried out by a contracted accredited laboratory — the Public Health Institute based in Hradec Králové (ČIA accreditation No. 1388, ČSN EN ISO/IEC 17025); dust composition is analysed by FTIR in cooperation with TUL Liberec.

How often does HVAC cleaning need to be done?+

The recommended HVAC cleaning interval depends on the type of operation and its load. Catering operations with greasy dust and healthcare facilities require more frequent maintenance than ordinary offices. After the first cleaning we propose a tailored regular-maintenance plan; premises with mechanical ventilation are required to document cleaning, which is exactly what our protocol provides.

What does the HVAC cleaning protocol contain?+

For every job we issue a cleaning protocol with before-and-after photo documentation. If you order a laboratory analysis, the test report is issued by an independent accredited laboratory and includes the values measured before and after cleaning (e.g. microbiological swabs in CFU/swab). The document is valid supporting evidence for hygiene inspections, the fire-safety officer, internal audits and occupational health and safety (OHS) documentation.

Is laboratory analysis included in the cleaning price?+

Laboratory analysis is an optional add-on service; it is not automatically part of the basic quote — you need to request it in advance. We commission the laboratory and you pay for it as part of the job. Before cleaning we take samples and determine the actual level of contamination; if the analysis shows that cleaning is not needed, you avoid unnecessary costs.

How does ordering work and how much does HVAC cleaning cost?+

After a non-binding inquiry we arrange a free inspection to determine the scope (optionally with a Wöhler SI 400 inspection camera). Within 3 days you receive an itemised quote with a fixed price and a schedule tailored to your operation. The price depends on the length and type of ductwork and the number of units, which is why we set it only after the inspection.

Will the cleaning disrupt our company's operations?+

No. We carry out HVAC cleaning outside your working hours — evenings, weekends and public holidays — so that employees are not burdened by dust and noise and operations continue without restriction.

Contact

Request a quote for HVAC cleaning.

Send us an inquiry or give us a call. We'll arrange a free site visit and within 3 days you'll have a fixed-price quote in hand.

Service area
Nationwide (Czechia)
Non-binding inquiry
Fill it out and we'll get back to you within 24 hours.

By submitting, you consent to the processing of your personal data for the purpose of handling your inquiry.